Sewage Treatment Plant

Sewage Treatment Plant Manufacturer & AMC Service in Pune & PCMC.

Engineered for zero-odor operation, 100% MPCB compliance, and up to 80% water recycling for flushing, landscaping, and HVAC cooling. Narmada Water Tech delivers compact, energy-efficient MBBR, SBR, and MBR Sewage Treatment Plants (5 KLD to 2000 KLD) for residential societies, commercial IT parks, hospitals, and industrial townships across Pune, Pimpri-Chinchwad, and MIDC corridors.

Advanced STP Technologies
MBBR, SBR, MBR & Extended Aeration

Selecting the Right Biological Treatment System for Your Facility.
Narmada Water Tech provides customized STP solutions for efficient sewage treatment and wastewater reuse.

Moving Bed Biofilm Reactor (MBBR)

The gold standard for Pune housing societies and commercial complexes. MBBR utilizes specially designed Virgin Polypropylene bio-carriers suspended in an actively aerated tank. The bio-carriers provide an expansive surface area (>800 m²/m³) for biofilm growth, delivering high BOD/COD removal within a 40% smaller footprint than conventional systems.

Membrane Bioreactor (MBR)

Combining activated sludge biological treatment with submerged ultrafiltration membranes (0.04-micron pore size). MBR eliminates the need for secondary clarifiers, producing crystal-clear, pathogen-free permeate water suitable for direct dual-plumbing toilet flushing, cooling towers, and vehicle washing.

Sequential Batch Reactor (SBR)

A cyclic biological treatment process where aeration, settling, and decanting occur in a single tank. Ideal for large societies, institutions, and industrial townships with varying wastewater flows.

Packaged & Containerized Skid STPs

Plug-and-play, factory-tested skids manufactured in mild steel epoxy-coated (MSEC) or FRP containers for rapid deployment with zero civil excavation.

Technical Comparison

MBBR vs. SBR vs. MBR

Key Performance Benchmarks for Engineers and Society Committees
Technical Parameter
MBBR Technology
SBR Technology
MBR Technology
Conventional ASP

BOD Removal Efficiency

90% - 95% (< 10 mg/L)

92% - 96% (< 10 mg/L)

98% - 99% (< 5 mg/L)

80% - 85% (< 30 mg/L)

COD Reduction

85% - 90% (< 50 mg/L)

85% - 92% (< 50 mg/L)

95% - 98% (< 30 mg/L)

75% - 80% (< 100 mg/L)

Footprint Requirement

Moderate (40% less than ASP)

Moderate to Large

Minimal (60% less than ASP)

Very Large

Civil vs. Skid Cost

Economical / Balanced

Medium Capital

Higher Initial CAPEX

High Civil Investment

Power Consumption

0.45 - 0.65 kWh/m³

0.55 - 0.75 kWh/m³

0.85 - 1.20 kWh/m³

0.60 - 0.80 kWh/m³

Treated Water Quality

Flushing & Gardening

Flushing & Irrigation

Ultra-pure Flush & HVAC

Requires Multi-stage Filters
Sludge Generation
Low (Stabilized)
Low to Moderate
Very Low
High (Requires Daily Handling)
Odor Profile

Zero Odor (Diffused Air)

Zero to Low Odor
Completely Enclosed Odorless
Moderate to High Odor Risk

5 KLD to 2000 KL

STP Plant Capacity Sizing Chart

Calculate the Exact Sewage Volume Required for Your Building

10 KLD to 25 KLD

Small residential apartments (20 - 45 flats), boutique hotels, clinics.

50 KLD to 100 KLD

Mid-sized housing societies and commercial complexes.

150 KLD to 350 KLD

Large housing societies, hospitals, and IT parks.

500 KLD to 2000 KLD

Mega townships, SEZs, PMRDA zones, and automobile industries.

100% MPCB Discharge Standards & Water Testing Guarantee

Protecting Housing Societies and Industries from Statutory Penalties

10 KLD to 25 KLD

6.5 to 8.5 (Neutralized & Safe)

Biological Oxygen Demand (BOD₅ at 20°C)

< 10 mg/L (Prescribed norm: < 20-30 mg/L)

Chemical Oxygen Demand (COD)

< 50 mg/L (Prescribed norm: < 100-250 mg/L)

Total Suspended Solids (TSS)

< 10 mg/L (Prescribed norm: < 30-50 mg/L)

Ammoniacal Nitrogen & Oil & Grease

< 5 mg/L

Fecal Coliform

<100 MPN/100 mL (UV / Chlorine Disinfection)

End-to-End STP Installation Workflow

From Site Survey to Commissioning

Rigorous 6-Stage Engineering Process for High Reliability

Step 01

Site Survey & Raw Sewage Characterization

Assessing inlet invert levels, sewer line routing, space constraints, and peak flow patterns.

Step 02

Process & Hydraulic Design

P&ID schematics, 3D GA drawings, tank sizing, and blower/pump duty-standby specifications.

Step 03

Precision In-House Fabrication

Skid Assembly, UPVC/SS304 Piping, Disc Diffusers & IP55 Control Panels – Pune Facility.

Step 03

Civil & Mechanical Integration

Tank waterproofing inspection, mechanical equipment erection, media loading, and non-return valve alignment.

Step 03

Biological Seeding & Commissioning

Microbial bio-culture inoculation, dissolved oxygen (DO) balancing (2.0 - 2.5 mg/L), and MLSS stabilization (3000 - 4500 mg/L).

Step 03

Operator Training & O&M Handover

Comprehensive SOP documentation, preventative maintenance checklists, and operator safety training.

Why Pune Societies & Builders Choose

Narmada Water Tech

Local Manufacturing, Rapid Spares, and Proven Track Record

In-House Fabrication in Pune

Fast delivery of replacement blowers, multi-port valves, dosing pumps, and filter media without third-party markups.

Zero-Odor Guarantee

Diffused aeration combined with automated biological inoculant dosing prevents anaerobic hydrogen sulfide (H₂S) gas generation.

2-Hour Emergency Breakdown SLA:

Rapid mobile response teams covering PCMC, Baner, Wakad, Hinjawadi, Kothrud, Hadapsar, and Chakan.

30% Energy Savings

Smart VFD automation and high-efficiency IE3 electric motors slash monthly society electricity bills.

Complete Turnkey Solutions

We handle civil skids, mechanical piping, electrical instrumentation, filtration, and annual O&M under a single roof.

Get Guaranteed MPCB-Compliant STP Manufacturer in Pune & PCMC

Contact our water treatment engineering specialists today for a free on-site effluent/water analysis, custom P&ID layout, and quotation with guaranteed 2-hour emergency service SLA.

support@narmadawatertech.com